CVE-2025-23363 (GCVE-0-2025-23363)

Vulnerability from cvelistv5 – Published: 2025-02-11 10:29 – Updated: 2025-06-10 15:17
VLAI?
Summary
A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions < V14.3.0.14), Teamcenter V2312 (All versions < V2312.0010), Teamcenter V2406 (All versions < V2406.0008), Teamcenter V2412 (All versions < V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link.
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Assigner
Impacted products
Vendor Product Version
Siemens Teamcenter V14.1 Affected: 0 , < * (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23363",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T16:25:01.651412Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T15:50:41.213Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V14.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V14.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V14.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V14.3.0.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V2312",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2312.0010",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V2406",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2406.0008",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Teamcenter V2412",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2412.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions \u003c V14.3.0.14), Teamcenter V2312 (All versions \u003c V2312.0010), Teamcenter V2406 (All versions \u003c V2406.0008), Teamcenter V2412 (All versions \u003c V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:H/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:22.287Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-656895.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-23363",
    "datePublished": "2025-02-11T10:29:02.933Z",
    "dateReserved": "2025-01-14T14:01:39.192Z",
    "dateUpdated": "2025-06-10T15:17:22.287Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-23363\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-02-11T11:15:16.250\",\"lastModified\":\"2025-09-24T00:58:03.703\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions \u003c V14.3.0.14), Teamcenter V2312 (All versions \u003c V2312.0010), Teamcenter V2406 (All versions \u003c V2406.0008), Teamcenter V2412 (All versions \u003c V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Teamcenter (todas las versiones anteriores a V14.3.0.0). El servicio de inicio de sesi\u00f3n SSO de las aplicaciones afectadas acepta entradas controladas por el usuario que podr\u00edan especificar un enlace a un sitio externo. Esto podr\u00eda permitir que un atacante redirija al usuario leg\u00edtimo a una URL elegida por el atacante para robar datos v\u00e1lidos de la sesi\u00f3n. Para que la vulnerabilidad se aproveche con \u00e9xito, el usuario leg\u00edtimo debe hacer clic activamente en un enlace creado por el atacante.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.3\",\"versionEndExcluding\":\"14.3.0.14\",\"matchCriteriaId\":\"1228F306-A2A2-4F0D-A008-B7FB72258710\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2312.0\",\"versionEndExcluding\":\"2312.0010\",\"matchCriteriaId\":\"2BDF20D2-7A74-425A-8620-43DF9FF8D944\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2406.0\",\"versionEndExcluding\":\"2406.0008\",\"matchCriteriaId\":\"8EA12964-7485-4E67-ACB8-AB20F387DCA6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2412.0\",\"versionEndExcluding\":\"2412.0004\",\"matchCriteriaId\":\"A3EC7C8A-965B-4F6F-B8D0-4E53EB7C04A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:14.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D654DEC7-0D54-454B-88DC-6E1475C51E44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:14.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7408DACC-970A-495E-87F4-B4A237FFE01C\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-656895.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-23363\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T16:25:01.651412Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T15:50:36.827Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.4, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:H/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Teamcenter V14.1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter V14.2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter V14.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V14.3.0.14\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter V2312\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2312.0010\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter V2406\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2406.0008\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter V2412\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2412.0004\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-656895.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Teamcenter V14.1 (All versions), Teamcenter V14.2 (All versions), Teamcenter V14.3 (All versions \u003c V14.3.0.14), Teamcenter V2312 (All versions \u003c V2312.0010), Teamcenter V2406 (All versions \u003c V2406.0008), Teamcenter V2412 (All versions \u003c V2412.0004). The SSO login service of affected applications accepts user-controlled input that could specify a link to an external site. This could allow an attacker to redirect the legitimate user to an attacker-chosen URL to steal valid session data. For a successful exploit, the legitimate user must actively click on an attacker-crafted link.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-601\", \"description\": \"CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-06-10T15:17:22.287Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-23363\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-10T15:17:22.287Z\", \"dateReserved\": \"2025-01-14T14:01:39.192Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2025-02-11T10:29:02.933Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…