icsa-22-347-03
Vulnerability from csaf_cisa
Published
2022-12-13 00:00
Modified
2023-01-19 00:00
Summary
Contec CONPROSYS HMI System (CHS)
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow a remote attacker to send specially crafted requests and cause a loss of sensitive information.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Japan
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Exploitability
No known public exploits specifically target this vulnerability.
{ "document": { "acknowledgments": [ { "names": [ "Floris Hendriks", "Jeroen Wijenbergh" ], "organization": "Radboud University", "summary": "reporting this vulnerability to Contec" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow a remote attacker to send specially crafted requests and cause a loss of sensitive information.", "title": "Risk evaluation" }, { "category": "other", "text": " Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": " Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": " Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-347-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-347-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-347-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-347-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" } ], "title": "Contec CONPROSYS HMI System (CHS)", "tracking": { "current_release_date": "2023-01-19T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-347-03", "initial_release_date": "2022-12-13T00:00:00.000000Z", "revision_history": [ { "date": "2022-12-13T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Contec CONPROSYS HMI System (CHS) Update A" }, { "date": "2023-01-19T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "Contec CONPROSYS HMI System (CHS) Update A (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 3.4.4", "product": { "name": "CONPROSYS HMI System (CHS): Ver.3.4.4 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CONPROSYS HMI System (CHS)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c= 3.4.5", "product": { "name": "CONPROSYS HMI System (CHS): Ver.3.4.5 and prior", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "CONPROSYS HMI System (CHS)" } ], "category": "vendor", "name": "Contec" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-44456", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "CONPROSYS HMI System versions 3.4.4 and prior are vulnerable to an OS Command Injection, which could allow an unauthenticated remote attacker to send specially crafted requests that could execute commands on the server. CVE-2022-44456 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-44456" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Contec recommends users update to CONPROSYS HMI System (CHS) Ver.3.5.0 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.contec.com/software-update/?year=d90a89d4-f21e-4fc2-bab0-291bb3d23495" } ], "scores": [ { "cvss_v3": { "baseScore": 10.0, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2023-22331", "cwe": { "id": "CWE-1392", "name": "Use of Default Credentials" }, "notes": [ { "category": "summary", "text": "In CONPROSYS HMI System Ver.3.4.5 and prior, user credential information could be altered by a remote unauthenticated attacker. CVE-2023-22331 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22331" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Contec recommends users update to CONPROSYS HMI System (CHS) Ver.3.5.0 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.contec.com/software-update/?year=d90a89d4-f21e-4fc2-bab0-291bb3d23495" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2023-22334", "cwe": { "id": "CWE-836", "name": "Use of Password Hash Instead of Password for Authentication" }, "notes": [ { "category": "summary", "text": "In CONPROSYS HMI System Ver.3.4.5 and prior, user credentials could be obtained via a machine-in-the-middle attack. CVE-2023-22334 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22334" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Contec recommends users update to CONPROSYS HMI System (CHS) Ver.3.5.0 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.contec.com/software-update/?year=d90a89d4-f21e-4fc2-bab0-291bb3d23495" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2023-22373", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "In CONPROSYS HMI System Ver.3.4.5 and prior, an arbitrary script could be executed on the web browser of the administrative user logging into the product. This could result in sensitive information being obtained. CVE-2023-22373 has been assigned to this vulnerability. A CVSS v3 base score of 5.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22373" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Contec recommends users update to CONPROSYS HMI System (CHS) Ver.3.5.0 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.contec.com/software-update/?year=d90a89d4-f21e-4fc2-bab0-291bb3d23495" } ], "scores": [ { "cvss_v3": { "baseScore": 5.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2023-22339", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "In CONPROSYS HMI System Ver.3.4.5 and prior, a remote unauthenticated attacker could obtain the server certificate, including the private key of the product. CVE-2023-22339 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-22339" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Contec recommends users update to CONPROSYS HMI System (CHS) Ver.3.5.0 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.contec.com/software-update/?year=d90a89d4-f21e-4fc2-bab0-291bb3d23495" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.