SSA-089022

Vulnerability from csaf_siemens - Published: 2026-01-28 00:00 - Updated: 2026-01-28 00:00
Summary
SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.3

Notes

Summary
SINEC OS before V3.3 contains third-party components with multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SINEC OS before V3.3 contains third-party components with multiple vulnerabilities.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.3 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-089022.html"
      },
      {
        "category": "self",
        "summary": "SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.3 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-089022.json"
      }
    ],
    "title": "SSA-089022: Multiple Vulnerabilities in Third-Party Components in SINEC OS before V3.3",
    "tracking": {
      "current_release_date": "2026-01-28T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-089022",
      "initial_release_date": "2026-01-28T00:00:00Z",
      "revision_history": [
        {
          "date": "2026-01-28T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "RUGGEDCOM RST2428P (6GK6242-6PA00)",
                  "product_id": "1",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK6242-6PA00"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM RST2428P (6GK6242-6PA00)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)",
                  "product_id": "2",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5328-4TS01-2EC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XCH328 (6GK5328-4TS01-2EC2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5324-8TS01-2AC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XCM324 (6GK5324-8TS01-2AC2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)",
                  "product_id": "4",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5328-4TS01-2AC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XCM328 (6GK5328-4TS01-2AC2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)",
                  "product_id": "5",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5332-0GA01-2AC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XCM332 (6GK5332-0GA01-2AC2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)",
                  "product_id": "6",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-2TS01-2ER3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)",
                  "product_id": "7",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-3TS01-3AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)",
                  "product_id": "8",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-2TS01-3AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)",
                  "product_id": "9",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-5TS01-3AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)",
                  "product_id": "10",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-3TS01-2AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)",
                  "product_id": "11",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-2TS01-2AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)",
                  "product_id": "12",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-5TS01-2AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)",
                  "product_id": "13",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-3TS01-4AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)",
                  "product_id": "14",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-2TS01-4AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/\u003c3.3",
                "product": {
                  "name": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)",
                  "product_id": "15",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5334-5TS01-4AR3"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-48174",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicles, this vulnerability can be executed from command to arbitrary code execution.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2022-48174"
    },
    {
      "cve": "CVE-2023-7256",
      "cwe": {
        "id": "CWE-415",
        "name": "Double Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In affected libpcap versions during the setup of a remote packet capture the internal function sock_initaddress() calls getaddrinfo() and possibly freeaddrinfo(), but does not clearly indicate to the caller function whether freeaddrinfo() still remains to be called after the function returns.  This makes it possible in some scenarios that both the function and its caller call freeaddrinfo() for the same allocated memory block.  A similar problem was reported in Apple libpcap, to which Apple assigned CVE-2023-40400.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-7256"
    },
    {
      "cve": "CVE-2023-39810",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue in the CPIO command of Busybox v1.33.2 allows attackers to execute a directory traversal.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-39810"
    },
    {
      "cve": "CVE-2023-42363",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A use-after-free vulnerability was discovered in xasprintf function in xfuncs_printf.c:344 in BusyBox v.1.36.1.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-42363"
    },
    {
      "cve": "CVE-2023-42364",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A use-after-free vulnerability in BusyBox v.1.36.1 allows attackers to cause a denial of service via a crafted awk pattern in the awk.c evaluate function.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-42364"
    },
    {
      "cve": "CVE-2023-42365",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A use-after-free vulnerability was discovered in BusyBox v.1.36.1 via a crafted awk pattern in the awk.c copyvar function.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-42365"
    },
    {
      "cve": "CVE-2023-42366",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A heap-buffer-overflow was discovered in BusyBox v.1.36.1 in the next_token function at awk.c:1159.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2023-42366"
    },
    {
      "cve": "CVE-2024-6197",
      "cwe": {
        "id": "CWE-590",
        "name": "Free of Memory not on the Heap"
      },
      "notes": [
        {
          "category": "summary",
          "text": "libcurl\u0027s ASN1 parser has this utf8asn1str() function used for parsing an ASN.1 UTF-8 string. Itcan detect an invalid field and return error. Unfortunately, when doing so it also invokes `free()` on a 4 byte localstack buffer.  Most modern malloc implementations detect this error and immediately abort. Some however accept the input pointer and add that memory to its list of available chunks. This leads to the overwriting of nearby stack memory. The content of the overwrite is decided by the `free()` implementation; likely to be memory pointers and a set of flags.  The most likely outcome of exploting this flaw is a crash, although it cannot be ruled out that more serious results can be had in special circumstances.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-6197"
    },
    {
      "cve": "CVE-2024-6874",
      "cwe": {
        "id": "CWE-126",
        "name": "Buffer Over-read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "libcurl\u0027s URL API function\n[curl_url_get()](https://curl.se/libcurl/c/curl_url_get.html) offers punycode\nconversions, to and from IDN. Asking to convert a name that is exactly 256\nbytes, libcurl ends up reading outside of a stack based buffer when built to\nuse the *macidn* IDN backend. The conversion function then fills up the\nprovided buffer exactly - but does not null terminate the string.\n\nThis flaw can lead to stack contents accidently getting returned as part of\nthe converted string.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-6874"
    },
    {
      "cve": "CVE-2024-7264",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "libcurl\u0027s ASN1 parser code has the `GTime2str()` function, used for parsing an ASN.1 Generalized Time field. If given an syntactically incorrect field, the parser might end up using -1 for the length of the *time fraction*, leading to a `strlen()` getting performed on a pointer to a heap buffer area that is not (purposely) null terminated. This flaw most likely leads to a crash, but can also lead to heap contents getting returned to the application when [CURLINFO_CERTINFO](https://curl.se/libcurl/c/CURLINFO_CERTINFO.html) is used.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-7264"
    },
    {
      "cve": "CVE-2024-8006",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Remote packet capture support is disabled by default in libpcap.  When a user builds libpcap with remote packet capture support enabled, one of the functions that become available is pcap_findalldevs_ex().  One of the function arguments can be a filesystem path, which normally means a directory with input data files.  When the specified path cannot be used as a directory, the function receives NULL from opendir(), but does not check the return value and passes the NULL value to readdir(), which causes a NULL pointer derefence.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-8006"
    },
    {
      "cve": "CVE-2024-8096",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When curl is told to use the Certificate Status Request TLS extension, often referred to as OCSP stapling, to verify that the server certificate is valid, it might fail to detect some OCSP problems and instead wrongly consider the response as fine. If the returned status reports another error than \u0027revoked\u0027 (like for example \u0027unauthorized\u0027) it is not treated as a bad certficate.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-8096"
    },
    {
      "cve": "CVE-2024-9681",
      "cwe": {
        "id": "CWE-697",
        "name": "Incorrect Comparison"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When curl is asked to use HSTS, the expiry time for a subdomain might\r\noverwrite a parent domain\u0027s cache entry, making it end sooner or later than\r\notherwise intended.\r\n\r\nThis affects curl using applications that enable HSTS and use URLs with the\r\ninsecure `HTTP://` scheme and perform transfers with hosts like\r\n`x.example.com` as well as `example.com` where the first host is a subdomain\r\nof the second host.\r\n\r\n(The HSTS cache either needs to have been populated manually or there needs to\r\nhave been previous HTTPS accesses done as the cache needs to have entries for\r\nthe domains involved to trigger this problem.)\r\n\r\nWhen `x.example.com` responds with `Strict-Transport-Security:` headers, this\r\nbug can make the subdomain\u0027s expiry timeout *bleed over* and get set for the\r\nparent domain `example.com` in curl\u0027s HSTS cache.\r\n\r\nThe result of a triggered bug is that HTTP accesses to `example.com` get\r\nconverted to HTTPS for a different period of time than what was asked for by\r\nthe origin server. If `example.com` for example stops supporting HTTPS at its\r\nexpiry time, curl might then fail to access `http://example.com` until the\r\n(wrongly set) timeout expires. This bug can also expire the parent\u0027s entry\r\n*earlier*, thus making curl inadvertently switch back to insecure HTTP earlier\r\nthan otherwise intended.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-9681"
    },
    {
      "cve": "CVE-2024-11053",
      "cwe": {
        "id": "CWE-200",
        "name": "Exposure of Sensitive Information to an Unauthorized Actor"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When asked to both use a `.netrc` file for credentials and to follow HTTP redirects, curl could leak the password used for the first host to the followed-to host under certain circumstances. This flaw only manifests itself if the netrc file has an entry that matches the redirect target hostname but the entry either omits just the password or omits both login and password.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-11053"
    },
    {
      "cve": "CVE-2024-12718",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Allows modifying some file metadata (e.g. last modified) with filter=\"data\"\u00a0or file permissions (chmod) with filter=\"tar\"\u00a0of files outside the extraction directory.\nYou are affected by this vulnerability if using the tarfile\u00a0module to extract untrusted tar archives using TarFile.extractall()\u00a0or TarFile.extract()\u00a0using the filter=\u00a0parameter with a value of \"data\"\u00a0or \"tar\". See the tarfile  extraction filters documentation https://docs.python.org/3/library/tarfile.html#tarfile-extraction-filter \u00a0for more information. Only Python versions 3.12 or later are affected by these vulnerabilities, earlier versions don\u0027t include the extraction filter feature.\n\nNote that for Python 3.14 or later the default value of filter=\u00a0changed from \"no filtering\" to `\"data\", so if you are relying on this new default behavior then your usage is also affected.\n\nNote that none of these vulnerabilities significantly affect the installation of source distributions which are tar archives as source distributions already allow arbitrary code execution during the build process. However when evaluating source distributions it\u0027s important to avoid installing source distributions with suspicious links.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-12718"
    },
    {
      "cve": "CVE-2024-41996",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Validating the order of the public keys in the Diffie-Hellman Key Agreement Protocol, when an approved safe prime is used, allows remote attackers (from the client side) to trigger unnecessarily expensive server-side DHE modular-exponentiation calculations. The client may cause asymmetric resource consumption. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE and validate the order of the public key.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-41996"
    },
    {
      "cve": "CVE-2024-47619",
      "cwe": {
        "id": "CWE-295",
        "name": "Improper Certificate Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "syslog-ng is an enhanced log daemo. Prior to version 4.8.2, `tls_wildcard_match()` matches on certificates such as `foo.*.bar` although that is not allowed. It is also possible to pass partial wildcards such as `foo.a*c.bar` which glib matches but should be avoided / invalidated. This issue could have an impact on TLS connections, such as in man-in-the-middle situations. Version 4.8.2 contains a fix for the issue.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-47619"
    },
    {
      "cve": "CVE-2024-52533",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "gio/gsocks4aproxy.c in GNOME GLib before 2.82.1 has an off-by-one error and resultant buffer overflow because SOCKS4_CONN_MSG_LEN is not sufficient for a trailing \u0027\\\\0\u0027 character.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2024-52533"
    },
    {
      "cve": "CVE-2025-0167",
      "cwe": {
        "id": "CWE-200",
        "name": "Exposure of Sensitive Information to an Unauthorized Actor"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When asked to use a .netrc file for credentials and to follow HTTP redirects, curl could leak the password used for the first host to the followed-to host under certain circumstances. This flaw only manifests itself if the netrc file has a default entry that omits both login and password. A rare circumstance.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-0167"
    },
    {
      "cve": "CVE-2025-0665",
      "cwe": {
        "id": "CWE-1341",
        "name": "Multiple Releases of Same Resource or Handle"
      },
      "notes": [
        {
          "category": "summary",
          "text": "libcurl would wrongly close the same eventfd file descriptor twice when taking down a connection channel after having completed a threaded name resolve.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-0665"
    },
    {
      "cve": "CVE-2025-0725",
      "cwe": {
        "id": "CWE-680",
        "name": "Integer Overflow to Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When libcurl is asked to perform automatic gzip decompression of content-encoded HTTP responses with the CURLOPT_ACCEPT_ENCODING option, using zlib 1.2.0.3 or older, an attacker-controlled integer overflow would make libcurl perform a buffer overflow.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-0725"
    },
    {
      "cve": "CVE-2025-1390",
      "cwe": {
        "id": "CWE-284",
        "name": "Improper Access Control"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The PAM module pam_cap.so of libcap configuration supports group names starting with \u201c@\u201d, during actual parsing, configurations not starting with \u201c@\u201d are incorrectly recognized as group names. This may result in nonintended users being granted an inherited capability set, potentially leading to security risks. Attackers can exploit this vulnerability to achieve local privilege escalation on systems where /etc/security/capability.conf is used to configure user inherited privileges by constructing specific usernames.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-1390"
    },
    {
      "cve": "CVE-2025-3360",
      "cwe": {
        "id": "CWE-190",
        "name": "Integer Overflow or Wraparound"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An integer overflow and buffer under-read in GLib occur when parsing a long invalid ISO 8601 timestamp with the g_date_time_new_from_iso8601() function.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-3360"
    },
    {
      "cve": "CVE-2025-4138",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Allows the extraction filter to be ignored, allowing symlink targets to point outside the destination directory, and the modification of some file metadata.\n\n\nYou are affected by this vulnerability if using the tarfile\u00a0module to extract untrusted tar archives using TarFile.extractall()\u00a0or TarFile.extract()\u00a0using the filter=\u00a0parameter with a value of \"data\"\u00a0or \"tar\". See the tarfile  extraction filters documentation https://docs.python.org/3/library/tarfile.html#tarfile-extraction-filter \u00a0for more information.\n\nNote that for Python 3.14 or later the default value of filter=\u00a0changed from \"no filtering\" to `\"data\", so if you are relying on this new default behavior then your usage is also affected.\n\nNote that none of these vulnerabilities significantly affect the installation of source distributions which are tar archives as source distributions already allow arbitrary code execution during the build process. However when evaluating source distributions it\u0027s important to avoid installing source distributions with suspicious links.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4138"
    },
    {
      "cve": "CVE-2025-4330",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Allows the extraction filter to be ignored, allowing symlink targets to point outside the destination directory, and the modification of some file metadata.\n\n\nYou are affected by this vulnerability if using the tarfile\u00a0module to extract untrusted tar archives using TarFile.extractall()\u00a0or TarFile.extract()\u00a0using the filter=\u00a0parameter with a value of \"data\"\u00a0or \"tar\". See the tarfile  extraction filters documentation https://docs.python.org/3/library/tarfile.html#tarfile-extraction-filter \u00a0for more information.\n\nNote that for Python 3.14 or later the default value of filter=\u00a0changed from \"no filtering\" to `\"data\", so if you are relying on this new default behavior then your usage is also affected.\n\nNote that none of these vulnerabilities significantly affect the installation of source distributions which are tar archives as source distributions already allow arbitrary code execution during the build process. However when evaluating source distributions it\u0027s important to avoid installing source distributions with suspicious links.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4330"
    },
    {
      "cve": "CVE-2025-4373",
      "cwe": {
        "id": "CWE-124",
        "name": "Buffer Underwrite (\u0027Buffer Underflow\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "GLib is vulnerable to an integer overflow in the g_string_insert_unichar() function. When the position at which to insert the character is large, the position will overflow, leading to a buffer underwrite.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4373"
    },
    {
      "cve": "CVE-2025-4435",
      "cwe": {
        "id": "CWE-682",
        "name": "Incorrect Calculation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "When using a TarFile.errorlevel = 0\u00a0and extracting with a filter the documented behavior is that any filtered members would be skipped and not extracted. However the actual behavior of TarFile.errorlevel = 0\u00a0in affected versions is that the member would still be extracted and not skipped.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4435"
    },
    {
      "cve": "CVE-2025-4516",
      "cwe": {
        "id": "CWE-416",
        "name": "Use After Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "There is an issue in CPython when using `bytes.decode(\"unicode_escape\", error=\"ignore|replace\")`. If you are not using the \"unicode_escape\" encoding or an error handler your usage is not affected. To work-around this issue you may stop using the error= handler and instead wrap the bytes.decode() call in a try-except catching the DecodeError.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4516"
    },
    {
      "cve": "CVE-2025-4517",
      "cwe": {
        "id": "CWE-22",
        "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Allows arbitrary filesystem writes outside the extraction directory during extraction with filter=\"data\".\n\n\nYou are affected by this vulnerability if using the tarfile\u00a0module to extract untrusted tar archives using TarFile.extractall()\u00a0or TarFile.extract()\u00a0using the filter=\u00a0parameter with a value of \"data\"\u00a0or \"tar\". See the tarfile  extraction filters documentation https://docs.python.org/3/library/tarfile.html#tarfile-extraction-filter \u00a0for more information.\n\nNote that for Python 3.14 or later the default value of filter=\u00a0changed from \"no filtering\" to `\"data\", so if you are relying on this new default behavior then your usage is also affected.\n\nNote that none of these vulnerabilities significantly affect the installation of source distributions which are tar archives as source distributions already allow arbitrary code execution during the build process. However when evaluating source distributions it\u0027s important to avoid installing source distributions with suspicious links.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-4517"
    },
    {
      "cve": "CVE-2025-6141",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A vulnerability has been found in GNU ncurses up to 6.5-20250322 and classified as problematic. This vulnerability affects the function postprocess_termcap of the file tinfo/parse_entry.c. The manipulation leads to stack-based buffer overflow. The attack needs to be approached locally. Upgrading to version 6.5-20250329 is able to address this issue. It is recommended to upgrade the affected component.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-6141"
    },
    {
      "cve": "CVE-2025-9086",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "1. A cookie is set using the `secure` keyword for `https://target`\n2. curl is redirected to or otherwise made to speak with `http://target` (same\n   hostname, but using clear text HTTP) using the same cookie set\n3. The same cookie name is set - but with just a slash as path (`path=\u0027/\u0027`).\n   Since this site is not secure, the cookie *should* just be ignored.\n4. A bug in the path comparison logic makes curl read outside a heap buffer\n   boundary\n\nThe bug either causes a crash or it potentially makes the comparison come to\nthe wrong conclusion and lets the clear-text site override the contents of the\nsecure cookie, contrary to expectations and depending on the memory contents\nimmediately following the single-byte allocation that holds the path.\n\nThe presumed and correct behavior would be to plainly ignore the second set of\nthe cookie since it was already set as secure on a secure host so overriding\nit on an insecure host should not be okay.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-9086"
    },
    {
      "cve": "CVE-2025-9230",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An application trying to decrypt CMS messages encrypted using password based encryption can trigger an out-of-bounds read and write. Impact summary: This out-of-bounds read may trigger a crash which leads to Denial of Service for an application. The out-of-bounds write can cause a memory corruption which can have various consequences including a Denial of Service or Execution of attacker-supplied code. Although the consequences of a successful exploit of this vulnerability could be severe, the probability that the attacker would be able to perform it is low. Besides, password based (PWRI) encryption support in CMS messages is very rarely used. For that reason the issue was assessed as Moderate severity according to our Security Policy. The FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-9230"
    },
    {
      "cve": "CVE-2025-9231",
      "cwe": {
        "id": "CWE-385",
        "name": "Covert Timing Channel"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Issue summary: A timing side-channel which could potentially allow remote\nrecovery of the private key exists in the SM2 algorithm implementation on 64 bit\nARM platforms.\n\nImpact summary: A timing side-channel in SM2 signature computations on 64 bit\nARM platforms could allow recovering the private key by an attacker..\n\nWhile remote key recovery over a network was not attempted by the reporter,\ntiming measurements revealed a timing signal which may allow such an attack.\n\nOpenSSL does not directly support certificates with SM2 keys in TLS, and so\nthis CVE is not relevant in most TLS contexts.  However, given that it is\npossible to add support for such certificates via a custom provider, coupled\nwith the fact that in such a custom provider context the private key may be\nrecoverable via remote timing measurements, we consider this to be a Moderate\nseverity issue.\n\nThe FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this\nissue, as SM2 is not an approved algorithm.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-9231"
    },
    {
      "cve": "CVE-2025-9232",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Issue summary: An application using the OpenSSL HTTP client API functions may\ntrigger an out-of-bounds read if the \u0027no_proxy\u0027 environment variable is set and\nthe host portion of the authority component of the HTTP URL is an IPv6 address.\n\nImpact summary: An out-of-bounds read can trigger a crash which leads to\nDenial of Service for an application.\n\nThe OpenSSL HTTP client API functions can be used directly by applications\nbut they are also used by the OCSP client functions and CMP (Certificate\nManagement Protocol) client implementation in OpenSSL. However the URLs used\nby these implementations are unlikely to be controlled by an attacker.\n\nIn this vulnerable code the out of bounds read can only trigger a crash.\nFurthermore the vulnerability requires an attacker-controlled URL to be\npassed from an application to the OpenSSL function and the user has to have\na \u0027no_proxy\u0027 environment variable set. For the aforementioned reasons the\nissue was assessed as Low severity.\n\nThe vulnerable code was introduced in the following patch releases:\n3.0.16, 3.1.8, 3.2.4, 3.3.3, 3.4.0 and 3.5.0.\n\nThe FIPS modules in 3.5, 3.4, 3.3, 3.2, 3.1 and 3.0 are not affected by this\nissue, as the HTTP client implementation is outside the OpenSSL FIPS module\nboundary.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-9232"
    },
    {
      "cve": "CVE-2025-10148",
      "cwe": {
        "id": "CWE-340",
        "name": "Generation of Predictable Numbers or Identifiers"
      },
      "notes": [
        {
          "category": "summary",
          "text": "curl\u0027s websocket code did not update the 32 bit mask pattern for each new\n outgoing frame as the specification says. Instead it used a fixed mask that\npersisted and was used throughout the entire connection.\n\nA predictable mask pattern allows for a malicious server to induce traffic\nbetween the two communicating parties that could be interpreted by an involved\nproxy (configured or transparent) as genuine, real, HTTP traffic with content\nand thereby poison its cache. That cached poisoned content could then be\nserved to all users of that proxy.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-10148"
    },
    {
      "cve": "CVE-2025-27587",
      "cwe": {
        "id": "CWE-385",
        "name": "Covert Timing Channel"
      },
      "notes": [
        {
          "category": "summary",
          "text": "OpenSSL 3.0.0 through 3.3.2 on the PowerPC architecture is vulnerable to a Minerva attack, exploitable by measuring the time of signing of random messages using the EVP_DigestSign API, and then using the private key to extract the K value (nonce) from the signatures. Next, based on the bit size of the extracted nonce, one can compare the signing time of full-sized nonces to signatures that used smaller nonces, via statistical tests. There is a side-channel in the P-364 curve that allows private key extraction (also, there is a dependency between the bit size of K and the size of the side channel). NOTE: This CVE is disputed because the OpenSSL security policy explicitly notes that any side channels which require same physical system to be detected are outside of the threat model for the software. The timing signal is so small that it is infeasible to be detected without having the attacking process running on the same physical system.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-27587"
    },
    {
      "cve": "CVE-2025-32433",
      "cwe": {
        "id": "CWE-306",
        "name": "Missing Authentication for Critical Function"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Erlang/OTP is a set of libraries for the Erlang programming language. Prior to versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20, a SSH server may allow an attacker to perform unauthenticated remote code execution (RCE). By exploiting a flaw in SSH protocol message handling, a malicious actor could gain unauthorized access to affected systems and execute arbitrary commands without valid credentials. This issue is patched in versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20. A temporary workaround involves disabling the SSH server or to prevent access via firewall rules.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 10.0,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-32433"
    },
    {
      "cve": "CVE-2025-38084",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nmm/hugetlb: unshare page tables during VMA split, not before\n\nCurrently, __split_vma() triggers hugetlb page table unsharing through\nvm_ops-\u003emay_split().  This happens before the VMA lock and rmap locks are\ntaken - which is too early, it allows racing VMA-locked page faults in our\nprocess and racing rmap walks from other processes to cause page tables to\nbe shared again before we actually perform the split.\n\nFix it by explicitly calling into the hugetlb unshare logic from\n__split_vma() in the same place where THP splitting also happens.  At that\npoint, both the VMA and the rmap(s) are write-locked.\n\nAn annoying detail is that we can now call into the helper\nhugetlb_unshare_pmds() from two different locking contexts:\n\n1. from hugetlb_split(), holding:\n    - mmap lock (exclusively)\n    - VMA lock\n    - file rmap lock (exclusively)\n2. hugetlb_unshare_all_pmds(), which I think is designed to be able to\n   call us with only the mmap lock held (in shared mode), but currently\n   only runs while holding mmap lock (exclusively) and VMA lock\n\nBackporting note:\nThis commit fixes a racy protection that was introduced in commit\nb30c14cd6102 (\"hugetlb: unshare some PMDs when splitting VMAs\"); that\ncommit claimed to fix an issue introduced in 5.13, but it should actually\nalso go all the way back.\n\n[jannh@google.com: v2]",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.0,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38084"
    },
    {
      "cve": "CVE-2025-38085",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nmm/hugetlb: fix huge_pmd_unshare() vs GUP-fast race\n\nhuge_pmd_unshare() drops a reference on a page table that may have\npreviously been shared across processes, potentially turning it into a\nnormal page table used in another process in which unrelated VMAs can\nafterwards be installed.\n\nIf this happens in the middle of a concurrent gup_fast(), gup_fast() could\nend up walking the page tables of another process.  While I don\u0027t see any\nway in which that immediately leads to kernel memory corruption, it is\nreally weird and unexpected.\n\nFix it with an explicit broadcast IPI through tlb_remove_table_sync_one(),\njust like we do in khugepaged when removing page tables for a THP\ncollapse.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38085"
    },
    {
      "cve": "CVE-2025-38086",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nnet: ch9200: fix uninitialised access during mii_nway_restart\n\nIn mii_nway_restart() the code attempts to call\nmii-\u003emdio_read which is ch9200_mdio_read(). ch9200_mdio_read()\nutilises a local buffer called \"buff\", which is initialised\nwith control_read(). However \"buff\" is conditionally\ninitialised inside control_read():\n\n        if (err == size) {\n                memcpy(data, buf, size);\n        }\n\nIf the condition of \"err == size\" is not met, then\n\"buff\" remains uninitialised. Once this happens the\nuninitialised \"buff\" is accessed and returned during\nch9200_mdio_read():\n\n        return (buff[0] | buff[1] \u003c\u003c 8);\n\nThe problem stems from the fact that ch9200_mdio_read()\nignores the return value of control_read(), leading to\nuinit-access of \"buff\".\n\nTo fix this we should check the return value of\ncontrol_read() and return early on error.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.0,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38086"
    },
    {
      "cve": "CVE-2025-38345",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nACPICA: fix acpi operand cache leak in dswstate.c\n\nACPICA commit 987a3b5cf7175916e2a4b6ea5b8e70f830dfe732\n\nI found an ACPI cache leak in ACPI early termination and boot continuing case.\n\nWhen early termination occurs due to malicious ACPI table, Linux kernel\nterminates ACPI function and continues to boot process. While kernel terminates\nACPI function, kmem_cache_destroy() reports Acpi-Operand cache leak.\n\nBoot log of ACPI operand cache leak is as follows:\n\u003e[    0.585957] ACPI: Added _OSI(Module Device)\n\u003e[    0.587218] ACPI: Added _OSI(Processor Device)\n\u003e[    0.588530] ACPI: Added _OSI(3.0 _SCP Extensions)\n\u003e[    0.589790] ACPI: Added _OSI(Processor Aggregator Device)\n\u003e[    0.591534] ACPI Error: Illegal I/O port address/length above 64K: C806E00000004002/0x2 (20170303/hwvalid-155)\n\u003e[    0.594351] ACPI Exception: AE_LIMIT, Unable to initialize fixed events (20170303/evevent-88)\n\u003e[    0.597858] ACPI: Unable to start the ACPI Interpreter\n\u003e[    0.599162] ACPI Error: Could not remove SCI handler (20170303/evmisc-281)\n\u003e[    0.601836] kmem_cache_destroy Acpi-Operand: Slab cache still has objects\n\u003e[    0.603556] CPU: 0 PID: 1 Comm: swapper/0 Not tainted 4.12.0-rc5 #26\n\u003e[    0.605159] Hardware name: innotek gmb_h virtual_box/virtual_box, BIOS virtual_box 12/01/2006\n\u003e[    0.609177] Call Trace:\n\u003e[    0.610063]  ? dump_stack+0x5c/0x81\n\u003e[    0.611118]  ? kmem_cache_destroy+0x1aa/0x1c0\n\u003e[    0.612632]  ? acpi_sleep_proc_init+0x27/0x27\n\u003e[    0.613906]  ? acpi_os_delete_cache+0xa/0x10\n\u003e[    0.617986]  ? acpi_ut_delete_caches+0x3f/0x7b\n\u003e[    0.619293]  ? acpi_terminate+0xa/0x14\n\u003e[    0.620394]  ? acpi_init+0x2af/0x34f\n\u003e[    0.621616]  ? __class_create+0x4c/0x80\n\u003e[    0.623412]  ? video_setup+0x7f/0x7f\n\u003e[    0.624585]  ? acpi_sleep_proc_init+0x27/0x27\n\u003e[    0.625861]  ? do_one_initcall+0x4e/0x1a0\n\u003e[    0.627513]  ? kernel_init_freeable+0x19e/0x21f\n\u003e[    0.628972]  ? rest_init+0x80/0x80\n\u003e[    0.630043]  ? kernel_init+0xa/0x100\n\u003e[    0.631084]  ? ret_from_fork+0x25/0x30\n\u003e[    0.633343] vgaarb: loaded\n\u003e[    0.635036] EDAC MC: Ver: 3.0.0\n\u003e[    0.638601] PCI: Probing PCI hardware\n\u003e[    0.639833] PCI host bridge to bus 0000:00\n\u003e[    0.641031] pci_bus 0000:00: root bus resource [io  0x0000-0xffff]\n\u003e ... Continue to boot and log is omitted ...\n\nI analyzed this memory leak in detail and found acpi_ds_obj_stack_pop_and_\ndelete() function miscalculated the top of the stack. acpi_ds_obj_stack_push()\nfunction uses walk_state-\u003eoperand_index for start position of the top, but\nacpi_ds_obj_stack_pop_and_delete() function considers index 0 for it.\nTherefore, this causes acpi operand memory leak.\n\nThis cache leak causes a security threat because an old kernel (\u003c= 4.9) shows\nmemory locations of kernel functions in stack dump. Some malicious users\ncould use this information to neutralize kernel ASLR.\n\nI made a patch to fix ACPI operand cache leak.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38345"
    },
    {
      "cve": "CVE-2025-38350",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nnet/sched: Always pass notifications when child class becomes empty\n\nCertain classful qdiscs may invoke their classes\u0027 dequeue handler on an\nenqueue operation. This may unexpectedly empty the child qdisc and thus\nmake an in-flight class passive via qlen_notify(). Most qdiscs do not\nexpect such behaviour at this point in time and may re-activate the\nclass eventually anyways which will lead to a use-after-free.\n\nThe referenced fix commit attempted to fix this behavior for the HFSC\ncase by moving the backlog accounting around, though this turned out to\nbe incomplete since the parent\u0027s parent may run into the issue too.\nThe following reproducer demonstrates this use-after-free:\n\n    tc qdisc add dev lo root handle 1: drr\n    tc filter add dev lo parent 1: basic classid 1:1\n    tc class add dev lo parent 1: classid 1:1 drr\n    tc qdisc add dev lo parent 1:1 handle 2: hfsc def 1\n    tc class add dev lo parent 2: classid 2:1 hfsc rt m1 8 d 1 m2 0\n    tc qdisc add dev lo parent 2:1 handle 3: netem\n    tc qdisc add dev lo parent 3:1 handle 4: blackhole\n\n    echo 1 | socat -u STDIN UDP4-DATAGRAM:127.0.0.1:8888\n    tc class delete dev lo classid 1:1\n    echo 1 | socat -u STDIN UDP4-DATAGRAM:127.0.0.1:8888\n\nSince backlog accounting issues leading to a use-after-frees on stale\nclass pointers is a recurring pattern at this point, this patch takes\na different approach. Instead of trying to fix the accounting, the patch\nensures that qdisc_tree_reduce_backlog always calls qlen_notify when\nthe child qdisc is empty. This solves the problem because deletion of\nqdiscs always involves a call to qdisc_reset() and / or\nqdisc_purge_queue() which ultimately resets its qlen to 0 thus causing\nthe following qdisc_tree_reduce_backlog() to report to the parent. Note\nthat this may call qlen_notify on passive classes multiple times. This\nis not a problem after the recent patch series that made all the\nclassful qdiscs qlen_notify() handlers idempotent.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38350"
    },
    {
      "cve": "CVE-2025-38498",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\ndo_change_type(): refuse to operate on unmounted/not ours mounts\n\nEnsure that propagation settings can only be changed for mounts located\nin the caller\u0027s mount namespace. This change aligns permission checking\nwith the rest of mount(2).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-38498"
    },
    {
      "cve": "CVE-2025-39839",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nbatman-adv: fix OOB read/write in network-coding decode\n\nbatadv_nc_skb_decode_packet() trusts coded_len and checks only against\nskb-\u003elen. XOR starts at sizeof(struct batadv_unicast_packet), reducing\npayload headroom, and the source skb length is not verified, allowing an\nout-of-bounds read and a small out-of-bounds write.\n\nValidate that coded_len fits within the payload area of both destination\nand source sk_buffs before XORing.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39839"
    },
    {
      "cve": "CVE-2025-39841",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nscsi: lpfc: Fix buffer free/clear order in deferred receive path\n\nFix a use-after-free window by correcting the buffer release sequence in\nthe deferred receive path. The code freed the RQ buffer first and only\nthen cleared the context pointer under the lock. Concurrent paths (e.g.,\nABTS and the repost path) also inspect and release the same pointer under\nthe lock, so the old order could lead to double-free/UAF.\n\nNote that the repost path already uses the correct pattern: detach the\npointer under the lock, then free it after dropping the lock. The\ndeferred path should do the same.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39841"
    },
    {
      "cve": "CVE-2025-39846",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\npcmcia: Fix a NULL pointer dereference in __iodyn_find_io_region()\n\nIn __iodyn_find_io_region(), pcmcia_make_resource() is assigned to\nres and used in pci_bus_alloc_resource(). There is a dereference of res\nin pci_bus_alloc_resource(), which could lead to a NULL pointer\ndereference on failure of pcmcia_make_resource().\n\nFix this bug by adding a check of res.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39846"
    },
    {
      "cve": "CVE-2025-39853",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\ni40e: Fix potential invalid access when MAC list is empty\n\nlist_first_entry() never returns NULL - if the list is empty, it still\nreturns a pointer to an invalid object, leading to potential invalid\nmemory access when dereferenced.\n\nFix this by using list_first_entry_or_null instead of list_first_entry.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39853"
    },
    {
      "cve": "CVE-2025-39860",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nBluetooth: Fix use-after-free in l2cap_sock_cleanup_listen()\n\nsyzbot reported the splat below without a repro.\n\nIn the splat, a single thread calling bt_accept_dequeue() freed sk\nand touched it after that.\n\nThe root cause would be the racy l2cap_sock_cleanup_listen() call\nadded by the cited commit.\n\nbt_accept_dequeue() is called under lock_sock() except for\nl2cap_sock_release().\n\nTwo threads could see the same socket during the list iteration\nin bt_accept_dequeue():\n\n  CPU1                        CPU2 (close())\n  ----                        ----\n  sock_hold(sk)               sock_hold(sk);\n  lock_sock(sk)   \u003c-- block close()\n  sock_put(sk)\n  bt_accept_unlink(sk)\n    sock_put(sk)  \u003c-- refcnt by bt_accept_enqueue()\n  release_sock(sk)\n                              lock_sock(sk)\n                              sock_put(sk)\n                              bt_accept_unlink(sk)\n                                sock_put(sk)        \u003c-- last refcnt\n                              bt_accept_unlink(sk)  \u003c-- UAF\n\nDepending on the timing, the other thread could show up in the\n\"Freed by task\" part.\n\nLet\u0027s call l2cap_sock_cleanup_listen() under lock_sock() in\nl2cap_sock_release().\n\n[0]:\nBUG: KASAN: slab-use-after-free in debug_spin_lock_before kernel/locking/spinlock_debug.c:86 [inline]\nBUG: KASAN: slab-use-after-free in do_raw_spin_lock+0x26f/0x2b0 kernel/locking/spinlock_debug.c:115\nRead of size 4 at addr ffff88803b7eb1c4 by task syz.5.3276/16995\nCPU: 3 UID: 0 PID: 16995 Comm: syz.5.3276 Not tainted syzkaller #0 PREEMPT(full)\nHardware name: QEMU Standard PC (Q35 + ICH9, 2009), BIOS 1.16.3-debian-1.16.3-2~bpo12+1 04/01/2014\nCall Trace:\n \u003cTASK\u003e\n __dump_stack lib/dump_stack.c:94 [inline]\n dump_stack_lvl+0x116/0x1f0 lib/dump_stack.c:120\n print_address_description mm/kasan/report.c:378 [inline]\n print_report+0xcd/0x630 mm/kasan/report.c:482\n kasan_report+0xe0/0x110 mm/kasan/report.c:595\n debug_spin_lock_before kernel/locking/spinlock_debug.c:86 [inline]\n do_raw_spin_lock+0x26f/0x2b0 kernel/locking/spinlock_debug.c:115\n spin_lock_bh include/linux/spinlock.h:356 [inline]\n release_sock+0x21/0x220 net/core/sock.c:3746\n bt_accept_dequeue+0x505/0x600 net/bluetooth/af_bluetooth.c:312\n l2cap_sock_cleanup_listen+0x5c/0x2a0 net/bluetooth/l2cap_sock.c:1451\n l2cap_sock_release+0x5c/0x210 net/bluetooth/l2cap_sock.c:1425\n __sock_release+0xb3/0x270 net/socket.c:649\n sock_close+0x1c/0x30 net/socket.c:1439\n __fput+0x3ff/0xb70 fs/file_table.c:468\n task_work_run+0x14d/0x240 kernel/task_work.c:227\n resume_user_mode_work include/linux/resume_user_mode.h:50 [inline]\n exit_to_user_mode_loop+0xeb/0x110 kernel/entry/common.c:43\n exit_to_user_mode_prepare include/linux/irq-entry-common.h:225 [inline]\n syscall_exit_to_user_mode_work include/linux/entry-common.h:175 [inline]\n syscall_exit_to_user_mode include/linux/entry-common.h:210 [inline]\n do_syscall_64+0x3f6/0x4c0 arch/x86/entry/syscall_64.c:100\n entry_SYSCALL_64_after_hwframe+0x77/0x7f\nRIP: 0033:0x7f2accf8ebe9\nCode: ff ff c3 66 2e 0f 1f 84 00 00 00 00 00 0f 1f 40 00 48 89 f8 48 89 f7 48 89 d6 48 89 ca 4d 89 c2 4d 89 c8 4c 8b 4c 24 08 0f 05 \u003c48\u003e 3d 01 f0 ff ff 73 01 c3 48 c7 c1 a8 ff ff ff f7 d8 64 89 01 48\nRSP: 002b:00007ffdb6cb1378 EFLAGS: 00000246 ORIG_RAX: 00000000000001b4\nRAX: 0000000000000000 RBX: 00000000000426fb RCX: 00007f2accf8ebe9\nRDX: 0000000000000000 RSI: 000000000000001e RDI: 0000000000000003\nRBP: 00007f2acd1b7da0 R08: 0000000000000001 R09: 00000012b6cb166f\nR10: 0000001b30e20000 R11: 0000000000000246 R12: 00007f2acd1b609c\nR13: 00007f2acd1b6090 R14: ffffffffffffffff R15: 00007ffdb6cb1490\n \u003c/TASK\u003e\n\nAllocated by task 5326:\n kasan_save_stack+0x33/0x60 mm/kasan/common.c:47\n kasan_save_track+0x14/0x30 mm/kasan/common.c:68\n poison_kmalloc_redzone mm/kasan/common.c:388 [inline]\n __kasan_kmalloc+0xaa/0xb0 mm/kasan/common.c:405\n kasan_kmalloc include/linux/kasan.h:260 [inline]\n __do_kmalloc_node mm/slub.c:4365 [inline]\n __kmalloc_nopro\n---truncated---",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39860"
    },
    {
      "cve": "CVE-2025-39864",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\nwifi: cfg80211: fix use-after-free in cmp_bss()\n\nFollowing bss_free() quirk introduced in commit 776b3580178f\n(\"cfg80211: track hidden SSID networks properly\"), adjust\ncfg80211_update_known_bss() to free the last beacon frame\nelements only if they\u0027re not shared via the corresponding\n\u0027hidden_beacon_bss\u0027 pointer.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39864"
    },
    {
      "cve": "CVE-2025-39865",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "In the Linux kernel, the following vulnerability has been resolved:\n\ntee: fix NULL pointer dereference in tee_shm_put\n\ntee_shm_put have NULL pointer dereference:\n\n__optee_disable_shm_cache --\u003e\n\tshm = reg_pair_to_ptr(...);//shm maybe return NULL\n        tee_shm_free(shm); --\u003e\n\t\ttee_shm_put(shm);//crash\n\nAdd check in tee_shm_put to fix it.\n\npanic log:\nUnable to handle kernel paging request at virtual address 0000000000100cca\nMem abort info:\nESR = 0x0000000096000004\nEC = 0x25: DABT (current EL), IL = 32 bits\nSET = 0, FnV = 0\nEA = 0, S1PTW = 0\nFSC = 0x04: level 0 translation fault\nData abort info:\nISV = 0, ISS = 0x00000004, ISS2 = 0x00000000\nCM = 0, WnR = 0, TnD = 0, TagAccess = 0\nGCS = 0, Overlay = 0, DirtyBit = 0, Xs = 0\nuser pgtable: 4k pages, 48-bit VAs, pgdp=0000002049d07000\n[0000000000100cca] pgd=0000000000000000, p4d=0000000000000000\nInternal error: Oops: 0000000096000004 [#1] SMP\nCPU: 2 PID: 14442 Comm: systemd-sleep Tainted: P OE ------- ----\n6.6.0-39-generic #38\nSource Version: 938b255f6cb8817c95b0dd5c8c2944acfce94b07\nHardware name: greatwall GW-001Y1A-FTH, BIOS Great Wall BIOS V3.0\n10/26/2022\npstate: 80000005 (Nzcv daif -PAN -UAO -TCO -DIT -SSBS BTYPE=--)\npc : tee_shm_put+0x24/0x188\nlr : tee_shm_free+0x14/0x28\nsp : ffff001f98f9faf0\nx29: ffff001f98f9faf0 x28: ffff0020df543cc0 x27: 0000000000000000\nx26: ffff001f811344a0 x25: ffff8000818dac00 x24: ffff800082d8d048\nx23: ffff001f850fcd18 x22: 0000000000000001 x21: ffff001f98f9fb88\nx20: ffff001f83e76218 x19: ffff001f83e761e0 x18: 000000000000ffff\nx17: 303a30303a303030 x16: 0000000000000000 x15: 0000000000000003\nx14: 0000000000000001 x13: 0000000000000000 x12: 0101010101010101\nx11: 0000000000000001 x10: 0000000000000001 x9 : ffff800080e08d0c\nx8 : ffff001f98f9fb88 x7 : 0000000000000000 x6 : 0000000000000000\nx5 : 0000000000000000 x4 : 0000000000000000 x3 : 0000000000000000\nx2 : ffff001f83e761e0 x1 : 00000000ffff001f x0 : 0000000000100cca\nCall trace:\ntee_shm_put+0x24/0x188\ntee_shm_free+0x14/0x28\n__optee_disable_shm_cache+0xa8/0x108\noptee_shutdown+0x28/0x38\nplatform_shutdown+0x28/0x40\ndevice_shutdown+0x144/0x2b0\nkernel_power_off+0x3c/0x80\nhibernate+0x35c/0x388\nstate_store+0x64/0x80\nkobj_attr_store+0x14/0x28\nsysfs_kf_write+0x48/0x60\nkernfs_fop_write_iter+0x128/0x1c0\nvfs_write+0x270/0x370\nksys_write+0x6c/0x100\n__arm64_sys_write+0x20/0x30\ninvoke_syscall+0x4c/0x120\nel0_svc_common.constprop.0+0x44/0xf0\ndo_el0_svc+0x24/0x38\nel0_svc+0x24/0x88\nel0t_64_sync_handler+0x134/0x150\nel0t_64_sync+0x14c/0x15",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.0,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-39865"
    },
    {
      "cve": "CVE-2025-59375",
      "cwe": {
        "id": "CWE-770",
        "name": "Allocation of Resources Without Limits or Throttling"
      },
      "notes": [
        {
          "category": "summary",
          "text": "libexpat in Expat before 2.7.2 allows attackers to trigger large dynamic memory allocations via a small document that is submitted for parsing.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13",
          "14",
          "15"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.3 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109997626/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13",
            "14",
            "15"
          ]
        }
      ],
      "title": "CVE-2025-59375"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…