A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Source | URL | Tags |
---|---|---|
cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf | Mitigation, Patch, Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:45.947Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GA-01-22320", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GS-01-22320", "versionType": "custom" } ] } ], "datePublic": "2023-04-11T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:50:53.336Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-29413", "datePublished": "2023-04-18T20:50:53.336Z", "dateReserved": "2023-04-05T20:35:41.367Z", "dateUpdated": "2024-08-02T14:07:45.947Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-29413\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-04-18T21:15:09.523\",\"lastModified\":\"2023-04-28T13:26:11.537\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\\nservice. \\n\\n \\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-ga-01-22320\",\"matchCriteriaId\":\"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-gs-01-22320\",\"matchCriteriaId\":\"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading...