CVE-2023-29412 (GCVE-0-2023-29412)
Vulnerability from cvelistv5 – Published: 2023-04-18 20:50 – Updated: 2025-02-05 21:00
VLAI
EPSS
VEX
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 21:00 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
guessed | |
| Schneider Electric | Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GS-01-22320 , ≤ prior
(custom)
|
guessed |
Date Public
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:00:28.496674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:00:38.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n"
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:20:18.929Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29412",
"datePublished": "2023-04-18T20:50:08.288Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:00:38.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-29412",
"date": "2026-09-18",
"epss": "0.01223",
"percentile": "0.67392"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296",
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B",
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"id": "CVE-2023-29412",
"lastModified": "2024-11-21T07:57:00.663",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-04-18T21:15:09.457",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"source": "cybersecurity@se.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296",
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B",
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"id": "CVE-2023-29412",
"lastModified": "2026-06-17T05:49:59.703",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-29412",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:00:28.496674Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-04-18T21:15:09.457",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:00:28.496674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:00:33.517Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n"
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:20:18.929Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29412",
"datePublished": "2023-04-18T20:50:08.288Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:00:38.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…