Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Version: V2.5-GA-01-22320 < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:45.947Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29413", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T20:59:10.323751Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:59:20.742Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GA-01-22320", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GS-01-22320", "versionType": "custom" } ] } ], "datePublic": "2023-04-11T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:50:53.336Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-29413", "datePublished": "2023-04-18T20:50:53.336Z", "dateReserved": "2023-04-05T20:35:41.367Z", "dateUpdated": "2025-02-05T20:59:20.742Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.5-ga-01-22320\", \"matchCriteriaId\": \"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21540673-614A-4D40-8BD7-3F07723803B0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\", \"matchCriteriaId\": \"647F2145-B063-43EA-8045-32D3B4D893F6\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DB79EE26-FC32-417D-A49C-A1A63165A968\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.5-gs-01-22320\", \"matchCriteriaId\": \"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21540673-614A-4D40-8BD7-3F07723803B0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\", \"matchCriteriaId\": \"647F2145-B063-43EA-8045-32D3B4D893F6\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DB79EE26-FC32-417D-A49C-A1A63165A968\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\\nservice. \\n\\n \\n\\n\\n\\n\"}]", "id": "CVE-2023-29413", "lastModified": "2024-11-21T07:57:00.790", "metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}", "published": "2023-04-18T21:15:09.523", "references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}]", "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2023-29413\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-04-18T21:15:09.523\",\"lastModified\":\"2024-11-21T07:57:00.790\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\\nservice. \\n\\n \\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-ga-01-22320\",\"matchCriteriaId\":\"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-gs-01-22320\",\"matchCriteriaId\":\"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T14:07:45.947Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-29413\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T20:59:10.323751Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T20:59:15.872Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.5-GA-01-22320\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.5-GS-01-22320\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"prior\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-04-11T07:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\\nservice. \\n\\n \\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\\nservice. \\n\\n \\n\\n\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-04-18T20:50:53.336Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2023-29413\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T20:59:20.742Z\", \"dateReserved\": \"2023-04-05T20:35:41.367Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-04-18T20:50:53.336Z\", \"assignerShortName\": \"schneider\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.