CVE-2024-41904 (GCVE-0-2024-41904)

Vulnerability from cvelistv5 – Published: 2024-08-13 07:54 – Updated: 2024-08-13 14:25
VLAI?
Summary
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Assigner
Impacted products
Vendor Product Version
Siemens SINEC Traffic Analyzer Affected: 0 , < V2.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinec_traffic_analyzer",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41904",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-13T14:24:06.374688Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-13T14:25:30.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SINEC Traffic Analyzer",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not properly enforce restriction of  excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:54:23.788Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-716317.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-41904",
    "datePublished": "2024-08-13T07:54:23.788Z",
    "dateReserved": "2024-07-23T10:56:51.268Z",
    "dateUpdated": "2024-08-13T14:25:30.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.0\", \"matchCriteriaId\": \"4B8318FF-CCF9-4240-AAE3-7D220039EF32\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not properly enforce restriction of  excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (Todas las versiones \u0026lt; V2.0). La aplicaci\\u00f3n afectada no aplica adecuadamente la restricci\\u00f3n de intentos de autenticaci\\u00f3n excesivos. Esto podr\\u00eda permitir que un atacante no autenticado realice ataques de fuerza bruta contra claves o credenciales de usuarios leg\\u00edtimos.\"}]",
      "id": "CVE-2024-41904",
      "lastModified": "2024-08-14T18:39:32.883",
      "metrics": "{\"cvssMetricV40\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"HIGH\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"NONE\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2024-08-13T08:15:13.003",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-716317.html\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Analyzed",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-307\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-41904\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-08-13T08:15:13.003\",\"lastModified\":\"2024-08-14T18:39:32.883\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not properly enforce restriction of  excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (Todas las versiones \u0026lt; V2.0). La aplicaci\u00f3n afectada no aplica adecuadamente la restricci\u00f3n de intentos de autenticaci\u00f3n excesivos. Esto podr\u00eda permitir que un atacante no autenticado realice ataques de fuerza bruta contra claves o credenciales de usuarios leg\u00edtimos.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-307\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0\",\"matchCriteriaId\":\"4B8318FF-CCF9-4240-AAE3-7D220039EF32\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-716317.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41904\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-13T14:24:06.374688Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"sinec_traffic_analyzer\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-13T14:25:13.847Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SINEC Traffic Analyzer\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-716317.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not properly enforce restriction of  excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-307\", \"description\": \"CWE-307: Improper Restriction of Excessive Authentication Attempts\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-08-13T07:54:23.788Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-41904\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-13T14:25:30.856Z\", \"dateReserved\": \"2024-07-23T10:56:51.268Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-08-13T07:54:23.788Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…