CVE-2025-40935 (GCVE-0-2025-40935)

Vulnerability from cvelistv5 – Published: 2025-12-09 10:44 – Updated: 2025-12-09 15:35
VLAI?
Summary
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RMC8388 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RS416Pv2 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RS416v2 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RS900 (32M) V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RS900G (32M) V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2100 (32M) V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2100P (32M) V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2288 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2300 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2300P V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG2488 V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG907R Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG908C Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG909R Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG910C Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSG920P V5.X Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RSL910 Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RST2228 Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RST2228P Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RST916C Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
    Siemens RUGGEDCOM RST916P Affected: 0 , < V5.10.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-40935",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-09T15:34:03.895420Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-09T15:35:36.265Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG907R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG908C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG909R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG910C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG907R (All versions \u003c V5.10.1), RUGGEDCOM RSG908C (All versions \u003c V5.10.1), RUGGEDCOM RSG909R (All versions \u003c V5.10.1), RUGGEDCOM RSG910C (All versions \u003c V5.10.1), RUGGEDCOM RSG920P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSL910 (All versions \u003c V5.10.1), RUGGEDCOM RST2228 (All versions \u003c V5.10.1), RUGGEDCOM RST2228P (All versions \u003c V5.10.1), RUGGEDCOM RST916C (All versions \u003c V5.10.1), RUGGEDCOM RST916P (All versions \u003c V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-09T10:44:34.649Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-763474.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-40935",
    "datePublished": "2025-12-09T10:44:34.649Z",
    "dateReserved": "2025-04-16T09:06:15.878Z",
    "dateUpdated": "2025-12-09T15:35:36.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-40935\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-12-09T16:17:47.070\",\"lastModified\":\"2025-12-09T18:36:53.557\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG907R (All versions \u003c V5.10.1), RUGGEDCOM RSG908C (All versions \u003c V5.10.1), RUGGEDCOM RSG909R (All versions \u003c V5.10.1), RUGGEDCOM RSG910C (All versions \u003c V5.10.1), RUGGEDCOM RSG920P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSL910 (All versions \u003c V5.10.1), RUGGEDCOM RST2228 (All versions \u003c V5.10.1), RUGGEDCOM RST2228P (All versions \u003c V5.10.1), RUGGEDCOM RST916C (All versions \u003c V5.10.1), RUGGEDCOM RST916P (All versions \u003c V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-763474.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-40935\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-09T15:34:03.895420Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-09T15:35:30.304Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RMC8388 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RS416Pv2 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RS416v2 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RS900 (32M) V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RS900G (32M) V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2100 (32M) V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2100P (32M) V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2288 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2300 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2300P V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG2488 V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG907R\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG908C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG909R\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG910C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSG920P V5.X\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RSL910\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RST2228\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RST2228P\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RST916C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RST916P\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.10.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-763474.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSG907R (All versions \u003c V5.10.1), RUGGEDCOM RSG908C (All versions \u003c V5.10.1), RUGGEDCOM RSG909R (All versions \u003c V5.10.1), RUGGEDCOM RSG910C (All versions \u003c V5.10.1), RUGGEDCOM RSG920P V5.X (All versions \u003c V5.10.1), RUGGEDCOM RSL910 (All versions \u003c V5.10.1), RUGGEDCOM RST2228 (All versions \u003c V5.10.1), RUGGEDCOM RST2228P (All versions \u003c V5.10.1), RUGGEDCOM RST916C (All versions \u003c V5.10.1), RUGGEDCOM RST916P (All versions \u003c V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20: Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-12-09T10:44:34.649Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-40935\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-09T15:35:36.265Z\", \"dateReserved\": \"2025-04-16T09:06:15.878Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2025-12-09T10:44:34.649Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…